请使用支持JavaScript的浏览器!
主要产品:NEB、内切酶、基因表达、RNAi DNA修饰酶、各种载体、 Marker 、引物、测序 等等
℡ 4000-520-616
℡ 4000-520-616
NEB/NEBNext® Globin & rRNA Depletion Kit (Human/Mouse/Rat)/6 reactions/E7750S
产品编号:E7750S
市  场 价:¥0.00
场      地:美国(厂家直采)
产品分类: 分子类>核酸酶类>其他>
联系QQ:1570468124
电话号码:4000-520-616
邮      箱: info@ebiomall.com
美  元  价:待定
品      牌: NEB
公      司:New England Biolabs
公司分类:
NEB/NEBNext® Globin & rRNA Depletion Kit (Human/Mouse/Rat)/6 reactions/E7750S
商品介绍

The great majority of RNA in blood samples is comprised of cytoplasmic and mitochondrial ribosomal RNAs (rRNA) and globin mRNA. These highly abundant RNA species can conceal the biological significance of less abundant transcripts, and so their efficient and specific removal is desirable.

The NEBNext® Globin & rRNA Depletion Kit (Human/Mouse/Rat) employs the NEBNext RNase H-based RNA depletion workflow to deplete adult, embryonic and fetal globin mRNA (HBA1/2, HBB, HBD, HBM, HBG1/2, HBE1, HBQ1 and HBZ), cytoplasmic rRNA (5S, 5.8S, 18S, 28S, ITS and ETS) and mitochondrial rRNA (12S and 16S).

The kit is effective with human, mouse and rat total RNA preparations, both intact and degraded. The resulting depleted RNA is suitable for RNA-seq, random-primed cDNA synthesis, or other downstream RNA analysis.

This kit can also be used following poly(A) mRNA enrichment (e.g., using the NEBNext poly(A) mRNA Magnetic Isolation Module NEB #E7490), so that the final depleted RNA contains only mRNA of interest and no non-coding RNA.The kit is also available with RNAClean® beads.Features

  • Efficient, specific depletion of rRNA and globin mRNA (adult, fetal and embryonic)
  • Suitable for low-quality or high-quality RNA
  • Compatible with a broad range of input amounts: 10 ng - 1 μg
  • Optional integration with poly(A) mRNA isolation workflows for removal of globin RNAs, rRNAs, and noncoding RNAs
  • Fast workflow: 2 hours, with less than 10 minutes hands-on time

For use with NEBNext Multiplex Oligos for Illumina (Unique Dual Index UMI Adaptors RNA Set 1) (NEB #E7416), refer to the Protocols tab for UMI Adaptors-specific guidance.

Figure 1. Depletion of globin mRNA and ribosomal RNA enriches for RNAs of interest across species
Human, mouse and rat whole blood total RNA (1 µg) was depleted of rRNA alone, or rRNA and globin mRNA transcripts, using the NEBNext Globin & rRNA Depletion Kit. RNA-seq libraries were prepared from untreated and depleted RNA using the NEBNext Ultra™ II RNA Library Prep Kit for Illumina® followed by paired-end sequencing (2 x 75 bp). Reads were identified as rRNA or globin mRNA using mirabait (6 or more, 25-mers), and levels of rRNA and globin mRNA remaining were calculated by dividing matched reads by the total number of reads passing instrument quality filtering.
Figure 2: Consistent Depletion Across Species and Across Inputs
Human, mouse and rat whole blood total RNA (1 µg, 100 ng and 10 ng) was depleted of rRNA and globin mRNA using the NEBNext Globin & rRNA Depletion Kit or Globin-Zero® Gold rRNA Depletion Kit (Illumina®). RNA-seq libraries were prepared from untreated and depleted RNA using the NEBNext Ultra™ II RNA Library Prep Kit for Illumina® followed by paired-end sequencing (2 x 75 bp). Reads were identified as ribosomal or globin using mirabait (6 or more, 25-mers), and levels of rRNA and globin mRNA remaining were calculated by dividing matched reads by the total number of reads passing instrument quality filtering. The data represents an average of 3 replicates and error bars indicate standard error. The NEBNext Globin Depletion Kit is superior at depleting rRNA across species, and at depleting over 99% of globin mRNA.
Figure 3: Transcript expression correlation is maintained after depletion
Human whole blood total RNA (1 µg) was depleted of rRNA and globin mRNA using the NEBNext Globin & rRNA Depletion Kit or Globin-Zero® Gold rRNA Depletion Kit (Illumina®). RNA-seq libraries were prepared from untreated and depleted RNA using the NEBNext Ultra™ II RNA Library Prep Kit for Illumina® followed by paired-end sequencing (2 x 75 bp). GENCODE v27 transcript abundances were estimated using Salmon. TPM (Transcript Per Million mapped reads) of protein coding transcripts, and R2 values for the linear fit are shown.Correlation analysis of the transcripts indicates better transcript expression correlation between depleted and undepleted samples for the NEBNext Globin & rRNA Depletion Kit. Treatment does not alter the abundances of non-targeted transcripts.
Figure 4: Transcript expression correlation is maintained across a range of input amounts
Human whole blood total RNA (1 µg, 100 ng and 10 ng) was depleted of rRNA and globin mRNA using the NEBNext Globin & rRNA Depletion Kit. RNA-seq libraries were prepared using the NEBNext Ultra™ II RNA Library Prep Kit for Illumina® followed by paired-end sequencing (2 x 75 bp). GENCODE v27 transcript abundances were estimated using Salmon. TPM (Transcript Per Million mapped reads) and R2 values for the linear fit are shown. Correlation analysis of the transcripts indicates consistent transcript expression regardless of input amount.
This product is related to the following categories:
RNA Depletion & mRNA Enrichment,
RNA Library Prep for Illumina
This product can be used in the following applications:
RNA-seq,
RNA Analysis
品牌介绍

NEB公司成立于二十世纪七十年代中期,拥有众多经验丰富的科学家,是生产生命科学试剂的领导者。目前,NEB为基因组研究提供最齐全的重组酶和天然酶,并且公司业务范围已延伸至蛋白质组学和药品开发领域。回顾三十余年来的历程,NEB公司作为先驱公司之一,为促进生物科技工业的发展做出了巨大的贡献。NEB美国总部乔 迁新址后拥有最尖端的设备,有一座现代化的发酵中心及设备齐全的实验室,这些实验室主要用于产品生产、质量监控、 产品开发和基础科研之用。作为首批以商业规模生产限制性内切酶的公司之一,NEB一直专注于内切酶的研究,并保持 业内领先水平。NEB公司一贯坚持以科学为本的原则,公司生产的试剂因其高质量、高性价比享誉世界。NEB(北京)有限公司 New England Biolabs (Beijing) LTD. NEB(北京)有限公司New England Biolabs (Beijing) LTD. 为美国New England Biolabs, Inc.在华投资兴建的独资子公司,负责处理其在中国内地及香港地区的全部业务,同时承担部分新产品的研发工作。纽英伦生物技术(北京)有限公司成立于2001年11月,为中国生命科学研究者提供一流的产品和专业的技术服务,促进国内外生命科学学术交流,与中国科研工作者一起将中国推入到二十一世纪生命科学的前沿中去。

自营商城图标
厂家直采
全球直采 正品优价
正品保障图标
正品保障
厂家直发 有线跟踪
解放采购图标
正规清关
CIF100%正规报关,提供发票
及时交付图标
及时交付
限时必达 不达必赔