商品介绍

Highly expressed transcripts with minimal biological interest, such as ribosomal RNA (rRNA) can dominate readouts, masking detection of more informative low-abundance transcripts. This second-generation NEBNext rRNA Depletion Kit is has been further optimized to incorporate reagent, probe and protocol improvements to the RNaseH-based workflow, resulting in superior depletion performance.

  • The efficiency of this workflow, and close spacing of probes, enables effective depletion from both low- and high-quality RNA, with a broad range of input amounts from human, mouse and rat samples.
  • The rRNA-depleted RNA can be used in RNA-seq, random-primed cDNA synthesis, or other RNA analysis methods.
  • The NEBNext® rRNA Depletion Kit v2 (Human/Mouse/Rat) depletes cytoplasmic (5S, 5.8S, 18S, 28S, human ITS, ETS) and mitochondrial (12S, 16S) rRNA.
  • The kit is also available with RNAClean® beads.
Figure 1: The NEBNext rRNA Depletion Kit v2 enriches for RNAs of interest across a wide range of total RNA inputs in human, mouse and rat
Universal human, mouse and rat reference total RNA (1 µg, 100 ng and 10 ng) was depleted of rRNA using the NEBNext rRNA Depletion Kit v2 (Human/Mouse/Rat). RNA-seq libraries were prepared using NEBNext Ultra II Directional RNA Library Prep Kit for Illumina followed by paired-end sequencing (2 x 75 bp). 10 Million reads were sampled (seqtk) from each library and reads were identified as ribosomal using mirabait (6 or more shared 25-mers) with rRNA sequences for human baits (5S, 5.8S, 12S, 16S, 18S, 28S, ETS/ITS) or mouse/rat baits (5S, 5.8S, 12S, 16S, 18S, 28S). Levels of rRNA remaining were calculated by dividing matched reads by the total number of reads passing instrument quality filtering. The data represents an average of 3 replicates. The NEBNext rRNA Depletion Kit v2 is efficient at depleting rRNA across species and input amounts.
Figure 2: Treatment with the NEBNext rRNA Depletion Kit v2 does not affect the abundances of non-targeted transcripts
Universal human, mouse and rat reference total RNA (1 µg) was depleted of rRNA using the NEBNext rRNA Depletion Kit v2 (Human/Mouse/Rat). RNA-seq libraries were prepared from untreated and depleted RNA using the NEBNext Ultra II Directional RNA Library Prep Kit for Illumina followed by paired-end sequencing (2 x 75bp). 10 million reads were sampled (seqtk) for depleted libraries and 100 million reads for undepleted libraries. GENCODE v27 transcript abundances were estimated using Salmon. Read Counts and R2 values for the linear fit are shown. Transcript expression is consistent after depletion across species.
Figure 3: Transcript expression correlation is preserved across a wide range of inputs
Universal human, mouse and rat reference total RNA (1 µg) was depleted of rRNA using the NEBNext rRNA Depletion Kit v2 (Human/Mouse/Rat). RNA-seq libraries were prepared using the NEBNext Ultra II Directional RNA Library Prep Kit for Illumina followed by paired-end sequencing (2 x 75bp). GENCODE v27 transcript abundances were estimated using Salmon. Read Counts and R2 values for the linear fit are shown. Transcript expression correlation is consistent regardless of input amount.
Figure 4: The NEBNext rRNA Depletion Kit v2 efficiently depletes rRNA from degraded FFPE total RNA while preserving transcript abundances
Human adult normal liver tissue FFPE Total RNA, RIN 2.3 (100 ng and 10 ng) was depleted of rRNA using the NEBNext rRNA Depletion Kit v2 (Human/Mouse/Rat) (A, B, C) or the TruSeq® Stranded Total RNA Gold kit (A). RNA-seq libraries were prepared using the NEBNext Ultra II Directional RNA Library Prep Kit for Illumina® followed by paired-end sequencing (2 x 75 bp). 20 Million reads were sampled (seqtk) from depleted libraries and 200 million reads from undepleted libraries. (A) Reads were identified as ribosomal using mirabait (6 or more shared 25-mers) with rRNA sequences for 5S, 5.8S, 12S, 16S, 18S, 28S and ETS/ITS as baits. Levels of rRNA remaining were calculated by dividing matched reads by the total number of reads passing instrument quality filtering. The data represents an average of 3 replicates and error bars indicate standard error. (B) and (C) GENCODE v27 transcript abundances were estimated using Salmon. Read Counts and R2 values for the linear fit are shown. The NEBNext kit provides superior depletion of rRNA from FFPE (degraded) samples and offers the flexibility of lower total RNA input amounts. Transcript expression correlation is consistent after treatment and regardless of input amount.
Figure 5: The NEBNext rRNA Depletion Kit v2 depletes both mature and pre-rRNA from human total RNA
Human universal reference total RNA (1 µg) was depleted of rRNA using the original NEBNext rRNA Depletion Kit (Human/Mouse/Rat) (NEB #E6310) and the NEBNext rRNA Depletion Kit v2 (Human/Mouse/Rat) (NEB #E7400). RNA-seq libraries were prepared using NEBNext Ultra II Directional RNA Library Prep Kit for Illumina followed by paired-end sequencing (2 x 75 bp). 10 Million reads were sampled (seqtk) from each library. Reads were identified as ribosomal using mirabait (6 or more shared 25-mers) with rRNA sequences for 5S, 5.8S 12S, 16S, 18S, 28S and ETS/ITS as baits. Levels of rRNA remaining were calculated by dividing matched reads by the total number of reads passing instrument quality filtering. The data represents an average of 3 replicates. NEBNext rRNA Depletion Kit v2 provide superior depletion of rRNA.
Figure 6: Workflow
This product is related to the following categories:
RNA Depletion & mRNA Enrichment,
RNA Library Prep for Illumina
This product can be used in the following applications:
RNA-seq,
RNA Analysis
品牌介绍

NEB公司成立于二十世纪七十年代中期,拥有众多经验丰富的科学家,是生产生命科学试剂的领导者。目前,NEB为基因组研究提供最齐全的重组酶和天然酶,并且公司业务范围已延伸至蛋白质组学和药品开发领域。回顾三十余年来的历程,NEB公司作为先驱公司之一,为促进生物科技工业的发展做出了巨大的贡献。NEB美国总部乔 迁新址后拥有最尖端的设备,有一座现代化的发酵中心及设备齐全的实验室,这些实验室主要用于产品生产、质量监控、 产品开发和基础科研之用。作为首批以商业规模生产限制性内切酶的公司之一,NEB一直专注于内切酶的研究,并保持 业内领先水平。NEB公司一贯坚持以科学为本的原则,公司生产的试剂因其高质量、高性价比享誉世界。NEB(北京)有限公司 New England Biolabs (Beijing) LTD. NEB(北京)有限公司New England Biolabs (Beijing) LTD. 为美国New England Biolabs, Inc.在华投资兴建的独资子公司,负责处理其在中国内地及香港地区的全部业务,同时承担部分新产品的研发工作。纽英伦生物技术(北京)有限公司成立于2001年11月,为中国生命科学研究者提供一流的产品和专业的技术服务,促进国内外生命科学学术交流,与中国科研工作者一起将中国推入到二十一世纪生命科学的前沿中去。